Which one is cheaper- Shanghai Dongfeng Pump Valve Factory - 上海花千坊_上海龙凤花坛_夜上海最新论坛

Which one is cheaper?

Which one is cheaper?

It mainly explains the additional code of pneumatic ball valve, pneumatic ball valve code, driving mode, connection form, structural form, sealing material, pressure rating, and valve body material. The preparation method of pneumatic ball valve model and the comparison description of pneumatic ball valve model code: pneumatic ball valve function code: V means the valve core has V-shaped structure, D means low temperature, B means insulation, P means eccentric structure U, S and DY mostly refer to top mounted type; Pneumatic ball valve drive code: 2 indicates electro-hydraulic, 3 indicates turbine, 6 indicates pneumatic, 7 indicates hydraulic, 9 indicates electric and manual without code;

 Pneumatic solenoid butterfly valve

Installation and commissioning methods and precautions for cylinder and valve body First, put the valve in the closed state with external force, first put the valve in the closed state with external force, that is, rotate the valve shaft clockwise until the valve plate contacts the valve seat seal, and at the same time, put the cylinder in the closed state (that is, the small groove above the cylinder shaft is vertical to the cylinder body for the valve that rotates clockwise to close the valve), Then install the cylinder onto the valve (the installation direction can be parallel or vertical to the valve body), and check whether the screw hole is aligned without too much deviation. If there is a little deviation, rotate the cylinder body a little, and then tighten the screws. For commissioning of pneumatic butterfly valve, first check whether the valve accessories are installed completely, solenoid valve, etc., if not, commissioning is not allowed. The normal air pressure of the feeder is 0.6MPA ± 0.05MPA. Before operation, ensure that there are no sundries stuck in the valve body at the valve plate. During commissioning, manually operate the solenoid valve manual button (the solenoid valve coil loses power during manual operation, and manual operation is effective; During the electric control operation, the manual operation is effective only when the manual knob is set to position 0 and the power is lost; Position 0 is to close the valve, position 1 is to open the valve, that is, to open the valve with power on. If the valve needs to be closed with power off, position 1 is to close the valve and rotate the solenoid valve coil 180 degrees for installation), and observe the operation status of the valve.

 Pneumatic solenoid butterfly valve

Previous: What equipment is the pneumatic rubber lined butterfly valve used for?

Next: What is the general flow requirement of pneumatic soft seal midline butterfly valve?