Installation of stainless steel electric butterfly valve How to deal with air leakage of high-speed railway electric butterfly valve
During the operation of high-speed railway electric butterfly valve, due to the influence of climate conditions, line conditions (especially when the curve is small radius), the quality of electric butterfly valve itself and other comprehensive factors, the electric butterfly valve may show air leakage. Cause analysis: air leakage of high-speed railway electric butterfly valve mainly occurs between the upper cover and the capsule. After 6~8 years of train operation, the data performance gradually ages, and the upper cover and capsule sealing part will also experience permanent deformation. When suddenly receiving a large transverse impact, the upper cover and capsule sealing part will show mismatch and air leakage will occur. Especially in winter when the temperature drops, the data performance becomes worse, and it is easier to show air leakage. Disposal method: refer to relevant technical requirements of metro, if the electric butterfly valve shows slight air leakage during vehicle operation, the main air duct pressure drop does not exceed 0.15 bar within 5 minutes of the vehicle air tightness test, it can continue to be used. If the leakage is exceeded, stop replacing the electric butterfly valve for maintenance.