What does Xiamen electric wafer stainless steel butterfly valve off stand for? Whether the fluid corrodes the pneumatic control valve. If the fluid to be controlled has relatively large corrosion in the process of using the pneumatic control valve, and the pneumatic control valve we use has no resistance to this corrosion, the quality of the pneumatic control valve will be directly affected after a period of use, The pneumatic control valve is quickly scrapped. According to different fluids and actual conditions, pneumatic control valves with different materials, or pneumatic control valves that have been treated with the fluid contact surface, can ensure that the pneumatic control valve will not be affected by the fluid.
、 Installation requirements of pneumatic butterfly valve
1. Before the device, check that all parts of the pneumatic butterfly valve are free of missing parts and correct types, check that there are no sundries in the valve body, and check that there are no blockages in the solenoid valve and silencer
2. Place the valve and cylinder in closed condition.
3. Install the cylinder onto the valve (the device direction can be parallel or straight with the valve body), and then check whether the screw hole is aligned without too much deviation. If there is a little deviation, rotate the cylinder body a little, and then tighten the screws.
4. After the completion of the device, the pneumatic butterfly valve shall be commissioned (under normal conditions, the air supply pressure is 0.4~0.6MPa). During the commissioning operation, the solenoid valve must be opened and closed manually (it can be used only after the solenoid valve coil is de energized), and the opening and closing conditions of the pneumatic butterfly valve shall be investigated. If during the commissioning and operation process, it is found that the valve has some difficulty at the beginning of the opening and closing process, and then it is normal, it is necessary to reduce the stroke of the cylinder (adjust the stroke adjustment screws at both ends of the cylinder a little bit inward together, when adjusting, it is necessary to run the valve to the opening position, and then turn off the air source to adjust again), until the valve opening and closing action is smooth and closed without leakage. It should also be noted that the adjustable silencer can regulate the opening and closing speed of the valve, but it should not be too small, or the valve may not act.
5. Defa should be dry in front of the device and should not be stored in the open air
6. Check the pipeline before installing the butterfly valve to ensure that there is no welding slag and other foreign matters in the pipeline
7. The manual opening and closing resistance of the butterfly valve body is moderate, and the torque of the butterfly valve matches the torque of the selected actuator.
8. The flange used for butterfly valve connection is correct, and the pipe clamp flange is consistent with the butterfly valve flange. It is suggested to use special flange for butterfly valve instead of flat welding flange.
9. It is recognized that the flange welding is correct, and the flange shall not be welded after the completion of the butterfly valve device to avoid burning the rubber parts.
10. The installed pipe flange shall be aligned with the butterfly valve.
11. Install all flange bolts and tighten them by hand. It will be recognized that the butterfly valve is aligned with the flange, and then carefully open and close the butterfly valve to ensure that it is sensitive to open and close.