How to slow down the portable pneumatic ball valve butterfly valve? How should natural gas pneumatic ball valve be maintained? Natural gas pneumatic ball valve is used as a valve for natural gas transmission and control. Since natural gas contains sulfur and sulfur dioxide, which is highly corrosive, and natural gas has the particularity of flammability and explosion, there are many differences between the installation, use, and later maintenance of natural gas pneumatic ball valve and ordinary pneumatic ball valve. Only correct use and maintenance can ensure safety.
Device of pneumatic butterfly valve:
1. When installing pneumatic butterfly valve, the bending radius shall not be less than 6 times of the hose outer diameter.
2. The spacing between fixed points shall not be greater than lm, and the spacing between pipe clamp and terminal, elbow midpoint should be 300mm
3. When connecting with embedded lamps or similar appliances, the fixed pipe clamp at its end should be installed at lm along the length of the hose from the edge of lamps and appliances.
4. The pneumatic butterfly valve shall be firmly grounded, but shall not be used as the grounding conductor of electrical equipment.