What are the schematic parts of electric high-temperature ball valve- Shanghai Dongfeng Pump Valve Factory - 上海花千坊_上海龙凤花坛_夜上海最新论坛

What are the schematic parts of electric high-temperature ball valve?

What are the schematic parts of electric high-temperature ball valve?

Precautions when using wire cutting process for double flange electric ball valve When using wire cutting process for double flange electric ball valve, the cutting process shall be applicable to the material to be cut, and there shall be no harmful defects such as cracks. Before cutting, material marks shall be transplanted to prevent mixing of materials. When the carbon steel Q235 steel plate is no longer machined, the oxide skin, slag, splash, etc. on the cutting surface shall be removed, and the cutting surface shall be treated flat. The steel edges after mechanical punching and shearing shall be free of cracks, burrs and missing edges. When the ambient temperature of carbon steel is lower than - 20 ℃ and that of alloy steel is lower than O ℃, mechanical punching and shearing is not suitable.
For the steel plate with cracks after wire cutting, heat treatment shall be carried out immediately after welding, or post heat treatment shall be carried out. The post weld heat treatment of double flange electric ball valve shall be carried out in accordance with DL/T752, but the maximum post weld heat treatment temperature shall be 20 ℃ - 30 ℃ lower than the minimum temperature of base metal and weld deposit metal on both sides.
Installation steps of double flange electric ball valve:
1. Loosen the middle gland nut to make the seal ring almost inoperable, and then adjust the short pipe, and adjust the size by 1/2 Δ L is the best, then adjust the joint, remove the first nut of the stud, make the pipe go through the center, and make the head of the stud align with the pipe flange hole, then one end can be installed. 2. The nuts shall be pressurized symmetrically and tightened gradually. 3. Install the flange at the other end by analogy.
4. Compress the gland nuts symmetrically and gradually to fit.
5. When working, if it is found that the local sealing is not tight, the gland nut can be pressed locally until there is no leakage. If the sealing at both ends is not tight, gradually tighten the nuts at both ends of the flange until there is no leakage.

 Electric high-temperature ball valve

Previous: Which one is cheaper for the material of electric ball valve for floor heating?

Next: What is the specification of v type electric ball valve?