Specification and model of Q941F electric ball valve are generally manual or electric now - Shanghai Dongfeng Pump Valve Factory - 上海花千坊_上海龙凤花坛_夜上海最新论坛

Q941F electric ball valve is generally manual or electric

Q941F electric ball valve specifications and models are generally manual or electric now?

1. During the construction of flexible electric ball valve pipeline, it is necessary to keep it in a natural state, and do not artificially deform the product during installation. When the pipeline medium is acid and alkali resistant, oil, high temperature and other special data, the joint with a gear higher than the working pressure of the pipeline shall be selected. The normal applicable medium of the flexible electric ball valve is ordinary water with a temperature of 0-60 ° C. The special medium such as oil, acid and alkali, high temperature and other corrosive and solid conditions should use the corresponding special resistant electric ball valve. It is not allowed to be used blindly or in general.
2. When the electric ball valve is connected with the pipe flange, the screw rod of the bolt shall extend to one end of the pipe flange to prevent the electric ball valve from being hit or punctured when the thread is pressed and expanded. It is necessary to press and tighten the bolts at each end symmetrically so that all the bolts are tightened together. In severe environment, in addition to flat washer, tension spring washer shall also be added to prevent nuts from loosening.
3. If the arch or high radian electric ball valve is used, it is necessary to select the stud bolt because the hexagon of the bolt is difficult to pass through the flange hole, and try to reduce the protruding thread of the ball end to prevent the ball valve from being hit and damaged early when it is pressurized and expanded. When the flexible valve electric ball valve is used at the inlet and outlet of the water pump, it should be located at the side of the water spring, and a metal reducing joint should be installed between it and the water spring, and it should be installed at the large diameter source of the reducing diameter.
4. When the pipe displacement is greater than or equal to the maximum compensation amount of the joint, the number of joints shall be added to parallel the displacement amount. It is prohibited to make the joint in the ultimate deflection displacement and error condition in order to adjust the deviation of the pipe, and it is not allowed to exceed the ultimate elasticity, displacement, deflection and other applications
5. High rise water supply or suspended water supply pipeline shall be fixed on the hanger, bracket or anchor bracket, and the joint shall not accept the component of the pipeline itself and axial force, otherwise the joint shall be equipped with anti pull off equipment (its acceptance force must be greater than the axial force of the pipeline). When using large diameter electric ball valves with a diameter of more than DN1000mm, in order to facilitate equipment and reduce labor intensity, a short pipe of appropriate length should be manufactured at one end of the flange. After the short pipe of the electric ball valve is connected with the pipe at the other end, the short pipe should be welded with the long pipe at the opposite end.

 Q941F Electric Ball Valve

Previous: Specification of electric quick installation ball valve Electric actuator power off valve position

Next: Which one is better to import micro electric ball valve?