Upgraded electromagnetic flowmeter - Shanghai Dongfeng Pump Valve Factory - 上海花千坊_上海龙凤花坛_夜上海最新论坛

Upgraded electromagnetic flowmeter

  • [Valve model]: DCLLJ-16
  • [Diameter specification]: DN200—2000mm
  • [Structure]: Straight through
  • [Valve body material]: Cast steel WCB, stainless steel 304, stainless steel 316
  • [Nominal pressure]: 1.0Mpa、1.6Mpa
  • [Applicable temperature]: 0-90°C
  • [Application Scope]: Industrial, agricultural, water conservancy, environmental sewage monitoring, urban water supply
Consult the manufacturer Online Message
  •  Upgraded electromagnetic flowmeter

Product features

It is widely used in the process flow measurement and control of industrial and agricultural production companies in petrochemical industry, iron and steel metallurgy, water supply and drainage, water conservancy irrigation, water treatment, sewage treatment stations (environmental protection sewage control, chemical sewage, electroplating sewage), paper making (pulp), mud, medicine, food, etc.

Electromagnetic flowmeter is a flowmeter for flow measurement according to Faraday's law of electromagnetic induction. The advantage of electromagnetic flowmeter is that the pressure loss is very small and the flow range can be measured is large. The ratio of the maximum flow to the minimum flow is generally more than 20:1. The applicable industrial pipe diameter range is wide, up to 3m. The output signal and the measured flow are linear, with high accuracy, and the measurable conductivity ≥ 5 μ S/cm of acid, alkali salt solution, water, sewage, corrosive liquid, mud, pulp, pulp and other fluid flows. It is widely used in the process flow measurement and control of industrial and agricultural production companies in petrochemical industry, iron and steel metallurgy, water supply and drainage, water conservancy irrigation, water treatment, sewage treatment stations (environmental protection sewage control, chemical sewage, electroplating sewage), paper making (pulp), mud, medicine, food, etc.

 

 



technical parameter

Upgraded precision flowmeter not imported

1. 0.02 second ultra fast response frequency, real-time monitoring of on-site flow

2. Lightning resistant, shockproof and anti-interference technology, more stable on site

3. Flow coefficient, output zero point double calibration standard, accurate measurement

4. Multiple signal outputs, multiple quality inspection functions

5. Follow JJG1033-2007 Electromagnetic Flowmeter Identification Procedure

6. Follow GB/T18659-2002 (IDT ISO9140:1991) Performance evaluation method of electromagnetic flowmeter for conductive liquid flow measurement in closed pipeline

7. Follow GB/T18660-2002 (IDT ISO6817:1992) Performance evaluation method of electromagnetic flowmeter for conductive liquid flow measurement in closed pipeline

Quotation process

Valve price:

Due to the different requirements of order quantity, packaging and delivery method, and the fluctuation of the price of valve raw materials, the price of valves will have a big difference immediately, so our products have not been marked with prices on the website, please understand.

If you select a valve product on this website and need to know the price or obtain relevant technical information, please contact us. We will reply immediately, and can select appropriate valve products for you according to your requirements, so that your procurement process is easy and pleasant.

Quotation process:

1. Please fax the name (or product model) of the valve you selected, the required order quantity, packaging requirements, delivery time, your company name, your company location and contact information to 021-36311208 Or telephone: 021-60547555。

2. After receiving the customer's purchase list, our company will provide the customer with various services such as valve quotation "price list", model selection "valve model" and technical guidance as soon as possible.

3. Specific matters: delivery date, special requirements, etc.

Ordering Instructions

1、 If the customer has special requirements for the product, the following instructions must be provided in the order contract:
(1) Valve body material (such as plastic, cast steel, stainless steel...)
(2) Connection type (such as flange, thread, clamp, etc.)
(3) Nominal diameter, pipe size
(4) Ambient temperature and pressure range
(5) Power supply voltage, air supply pressure
(6) Fluid properties (including nominal pressure, temperature, viscosity or acid-base)
2、 The company configures various driving devices according to the special requirements of customers. (electric control, pneumatic control)
3、 If the customer provides the determined valve type and model, the customer should correctly explain the meaning and requirements of the model (see the description of valve model preparation for details), and sign the contract on the condition that both the supplier and the buyer have the same understanding.
4、 After the customer tells the required valve model, specification, quantity, delivery time and place, the deposit of 20% of the total amount or the full payment for goods shall be remitted to our company's account in time, and the rest of the payment for goods shall be remitted before shipment, so as to arrange shipment in time.
5、 After the purchase is confirmed, our company will produce in strict accordance with the delivery date. The product processing cycle is generally 3 to 30 days, depending on the type and quantity of the order, and the specific delivery time is subject to the contract. In order to ensure that the goods you ordered are in place in time, please try your best to order earlier.
6、 Our company provides network distribution services according to the needs of customers, delivering goods to the branches (offices) of customers in major cities, and implementing door-to-door delivery services. After the products are accepted, our company will provide after-sales service.